2B006Dimensional inspection or measuring systems, equipment, position feedback units and "electronic assemblies", as follows:

List
EU dual-use list – Annex I to Regulation (EU) 2021/821, updated annually
Originating regime
Thỏa ước Wassenaar
a. Computer controlled or "numerical controlled" Coordinate Measuring Machines (CMM), having a three dimensional (volumetric) maximum permissible error of length measurement (E0,MPE) at any point within the operating range of the machine (i.e., within the length of axes) equal to or less (better) than (1,7 + L/1 000 ) μm (L is the measured length in mm), according to ISO 10360-2:2009;
Technical Note:
For the purposes of 2B006.a., the E0,MPE of the most accurate configuration of the CMM specified by the manufacturer (e.g., best of the following: probe, stylus length, motion parameters, environment) and with "all compensations available" shall be compared to the 1,7+L/1 000 μm threshold.
N.B. SEE ALSO 2B206.
b. Linear displacement measuring instruments or systems, linear position feedback units, and "electronic assemblies", as follows:
Note:
Interferometer and optical-encoder measuring systems containing a "laser" are only specified in 2B006.b.3 and 2B206.c.
1. 'Non-contact type measuring systems' with a 'resolution' equal to or less (better) than 0,2 μm within 0 to 0,2 mm of the 'measuring range';
Technical Notes:
For the purposes of 2B006.b.1.:
1. 'Non -contact type measuring systems' are designed to measure the distance between the probe and measured object along a single vector, where the probe or measured object is in motion.
2. 'Measuring range' means the distance between the minimum and maximum working distance.
2. Linear position feedback units specially designed for machine tools and having an overall "accuracy" less (better) than (800 + (600 × L/1 000 )) nm (L equals effective length in mm);
3. Measuring systems having all of the following:
a. Containing a "laser";
b. A 'resolution' over their full scale of 0,200 nm or less (better); and
c. Capable of achieving a "measurement uncertainty" equal to or less (better) than (1,6 + L/2 000 ) nm (L is the measured length in mm) at any point within a measuring range, when compensated for the refractive index of air and measured over a period of 30 seconds at a temperature of 20 ± 0,01 °C;
4. "Electronic assemblies" specially designed to provide feedback capability in systems specified in 2B006.b.3.;
Technical Note:
For the purposes of 2B006.b., 'resolution' is the least increment of a measuring device; on digital instruments, the least significant bit.
c. Rotary position feedback units specially designed for machine tools or angular displacement measuring instruments, having an angular position "accuracy" equal to or less (better) than 0,9 second of arc;
Note:
2B006.c. does not control optical instruments, such as autocollimators, using collimated light (e.g. "laser" light) to detect angular displacement of a mirror.
d. Equipment for measuring surface roughness (including surface defects), by measuring optical scatter with a sensitivity of 0,5 nm or less (better).
Note:
2B006 includes machine tools, other than those specified in 2B001, that can be used as measuring machines if they meet or exceed the criteria specified for the measuring machine function.