- List
- Wassenaar Arrangement – List of Dual-Use Goods and Technologies – WA-LIST (25) 1
- Corresponding EU entry
- 6E003
a. ACOUSTICS - None
b. OPTICAL SENSORS - None
c. CAMERAS - None
OPTICS
d. "Technology" as follows:
1. "Technology" "required" for the coating and treatment of optical surfaces to achieve an 'optical thickness' uniformity of 99.5% or better for optical coatings 500 mm or more in diameter or major axis length and with a total loss (absorption and scatter) of less than 5 x 10⁻³;
N.B. See also 2.E.3.f.
Technical Note
For the purposes of 6.E.3.d.1., 'optical thickness' is the mathematical product of the index of refraction and the physical thickness of the coating.
2. "Technology" for the fabrication of optics using single point diamond turning techniques to produce surface finish "accuracies" of less (better) than 10 nm rms on non-planar surfaces exceeding 0.5 m²;
LASERS
e. "Technology" "required" for the "development", "production" or "use" of specially designed diagnostic instruments or targets in test facilities for "SHPL" testing or testing or evaluation of materials irradiated by "SHPL" beams;
f. MAGNETIC AND ELECTRIC FIELD SENSORS - Not used since 2004
g. GRAVIMETERS - None
h. RADAR - None
[1] ^(.) * The Russian Federation and Ukraine view this list as a reference list drawn up to help in the selection of dual-use goods which could contribute to the indigenous development, production or enhancement of conventional munitions capabilities.
b. OPTICAL SENSORS - None
c. CAMERAS - None
OPTICS
d. "Technology" as follows:
1. "Technology" "required" for the coating and treatment of optical surfaces to achieve an 'optical thickness' uniformity of 99.5% or better for optical coatings 500 mm or more in diameter or major axis length and with a total loss (absorption and scatter) of less than 5 x 10⁻³;
N.B. See also 2.E.3.f.
Technical Note
For the purposes of 6.E.3.d.1., 'optical thickness' is the mathematical product of the index of refraction and the physical thickness of the coating.
2. "Technology" for the fabrication of optics using single point diamond turning techniques to produce surface finish "accuracies" of less (better) than 10 nm rms on non-planar surfaces exceeding 0.5 m²;
LASERS
e. "Technology" "required" for the "development", "production" or "use" of specially designed diagnostic instruments or targets in test facilities for "SHPL" testing or testing or evaluation of materials irradiated by "SHPL" beams;
f. MAGNETIC AND ELECTRIC FIELD SENSORS - Not used since 2004
g. GRAVIMETERS - None
h. RADAR - None
[1] ^(.) * The Russian Federation and Ukraine view this list as a reference list drawn up to help in the selection of dual-use goods which could contribute to the indigenous development, production or enhancement of conventional munitions capabilities.