Sunday, 1 November 2026
Standing Office 81 (SOVNPA 81) emblem Viet Nam NVietnam National Presiding Agency
on Countering the Proliferation of Weapons of Mass Destruction
Standing Office 81

1.9.Heat exchangers

List
NSG – Trigger List (Part 1) – INFCIRC/254/Rev.15/Part 1 (21 April 2026)
(a) Steam generators especially designed or prepared for the primary or intermediate coolant circuit of a nuclear reactor as defined in paragraph 1.1. above.
(b) Other heat exchangers especially designed or prepared for use in the primary coolant circuit of a nuclear reactor as defined in paragraph 1.1. above.
EXPLANATORY NOTE
Steam generators are especially designed or prepared to transfer the heat generated in the reactor to the feed water for steam generation. In the case of a fast reactor for which an intermediate coolant loop is also present, the steam generator is in the intermediate circuit.
In a gas-cooled reactor, a heat exchanger may be utilised to transfer heat to a secondary gas loop that drives a gas turbine.
The scope of control for this entry does not include heat exchangers for the supporting systems of the reactor (e.g., the emergency cooling system or the decay heat cooling system).